Place of Origin : China
Brand Name : HENTG Power
Model Number : ZGS Series
Price : CN¥64,81-284,75/sets
Certification : CE
MOQ : 1
Frequency : 50Hz, 60Hz, 50/60Hz
Phase : Three
Coil Number : Multi Winding, Two Windings, Single Winding, Three Windings
application : distribution system
Output Voltage : 415V, 110V, 220V, 380V, 400V , 440V, 480V, 11kV
Input Voltage : 10.5kV, 3kV, 12.47kV, 6.6kV, 6.3kV, 6kV, 10kV, 35kV, 69kV, 110kV, 115kV, 132kV, 220kV
Type : Isolation Transformer, Voltage Regulator Transformer, AUTOTRANSFORMER, Field Adjustable Transformer, Oil-Immersed Transformer, Dual Winding Transformer, Oil-Immersed Transformer
Product name : Three Phase Oil Immersed Transformer
Application : Power Distribution System Power Transformer
| Attribute | Value |
|---|---|
| Frequency | 50Hz, 60Hz, 50/60Hz |
| Phase | Three |
| Coil Number | Multi Winding, Two Windings, Single Winding, Three Windings |
| Application | Distribution System |
| Output Voltage | 415V, 110V, 220V, 380V, 400V, 440V, 480V, 11kV |
| Input Voltage | 10.5kV, 3kV, 12.47kV, 6.6kV, 6.3kV, 6kV, 10kV, 35kV, 69kV, 110kV, 115kV, 132kV, 220kV |
| Type | Isolation Transformer, Voltage Regulator Transformer, AUTOTRANSFORMER, Field Adjustable Transformer, Oil-Immersed Transformer, Dual Winding Transformer |
| Product Name | Three Phase Oil Immersed Transformer |
Compact Prefabricated Substation | 30KVA~2500KVA | Integrated Power Solution
HENTG Power's compact prefabricated substation (also known as unit substation) is ideal for urban grids, industrial parks, solar/wind farms, and commercial facilities. With a compact footprint, fast deployment, and reliable operation, it meets your demands for both space and efficiency.
| HV Specifications | ||
|---|---|---|
| Rated Frequency | Hz | 50 |
| Rated Voltage | kV | 6, 10, 35 |
| Max Working Voltage | kV | 6.9, 11.5, 40.5 |
| Industrial Frequency Voltage-resisting Time | kV | 32/36, 42/48, 95/118 |
| Thunder and Lighting Ballistic Voltage-resisting Time | kV | 60/70, 75/85, 185/215 |
| Rated Current | A | 400, 630 |
| Rated Brief-period Current-resisting | kA | 12.5(2s), 16(2s), 20(2s) |
| Rated Crest Value Current-resisting | kA | 32.5, 40, 50 |
| LV Specifications | ||
| Rated Voltage | V | 380, 220 |
| Rated Current Of Major Return Circuit | A | 100-3200 |
| Rated short-circuit Current-resisting | kA | 15, 30, 50 |
| Rated Crest Value Current-resisting | kA | 30, 63, 110 |
| Branch Circuit | A | 10-800 |
| Quantity Of Branch | line | 1-12 |
| Compensation Circuit | kVAR | 0-360 |
| Transformer Specifications | ||
| Rated Capacity | kVA | 50-2000 |
| Short-circuit Impedance | % | 4, 6 |
| Scope Of Branch Connection | +2x2.5% ±5% | |
| Vector Group | Yyn0 Dyn11 | |
|
|